APPLICATION

18
2021-03

Working environment requirements and precautions of IR heating pipes


Contact us


Infrared heating tubes are energized heating equipment, so safety should be emphasized when using them. After all, accidents caused by electricity are very serious. The manufacturers of IR heating tube  will talk about the working environment requirements and precautions of IR heating tubes.

1. The magnesium oxide powder at the outlet end of the electric heating tube should avoid the infiltration of pollutants and moisture in the place of use to prevent leakage accidents.
2. The components are allowed to work under the following conditions.
A. The relative humidity of the air is not more than 95%, and there is no explosive and corrosive gas.
B. The working voltage should not be greater than 1.1 times the rated value, and the shell should be effectively grounded to the heating tube.
C. Insulation resistance ≥ 1MΩ Dielectric strength: 2KV/1min.
3. IR heating tube should be well positioned and fixed, and the effective heating area must be completely immersed in liquid or metal solid, and empty burning is strictly prohibited. When it is found that there is scale or carbon on the surface of the pipe body, it should be cleaned up and used in time, so as not to affect the heat dissipation and shorten the service life.
4. When heating fusible metals or solid nitrates, alkalis, bitumen, paraffin, etc., the operating voltage should be lowered first, and the voltage can be increased to the rated voltage after the dielectric heating tube is melted.
5. When heating the air, the components should be arranged crosswise and evenly, so that the components have good heat dissipation conditions, so that the air flowing through can be fully heated.
6. Safety measures should be considered when heating nitrate to prevent explosion accidents.
7. The wiring part should be placed outside the insulation layer to avoid contact with corrosive, explosive media and moisture; the lead wire heating tube should be able to withstand the temperature and heating load of the wiring part for a long time, and excessive force should be avoided when the wiring screws are tightened.
8. The components should be stored in a dry place. If the insulation resistance is lower than 1MΩ due to long-term storage, they can be dried in an oven at around 200°C, or the voltage can be reduced and heated until the insulation resistance is restored.



TAGS




Recommended Products

Infrared heat lamps with X base

IR ray is a kind of electromagnetic wave. It transmits energy at the speed of light. The energy from the sun mostly transmits...

Single Ruby Infrared Heat Lamps with R7s base

220V 300W/500W 118mm Single Spiral IR Halogen Lamp R7S Heating Drying Painting Quartz 24hours Customer Support...

500W~3000W Single tube infrared halogen heater lamp

*High quality high-temperature quartz glass. *Is totally transparent at IR radiation....

5000W Type Halogen Lamps ,5000W IR lamp

Simple mains operation,No transformer required.Higher luminous efficiency from lower power consumption.Reinforced filament su...

Ozone Free Quartz Tubing

Ozone free Quartz Tubing, clear cut surface slight purple. The product blocks wave length <220nm. Which transit over 70% i...

Click Here to leave a message
Hi! Please leave a message and our team will reach out to you at the earliest.

* indicates a required field